Centrifugal pump with double entry D 4000-95-2
Centrifugal pump with double entry D4000-95-2 are designed for pumping of water and liquids having properties in viscosity and chemical reactivity similar to water, with temperatures up to 85 C °, with a content of solid inclusions not exceeding 0.05% by weight, with their maximum size of 0.2 mm, with microhardness not more than 6.5 MPa (650 kgf / mm²).
Pumps are manufactured in a climatic category of a moderately cold climate – they are designed for macroclimatic regions with temperate and cold climates, placement category 4 – operation in rooms (volumes) with artificially controlled climate conditions, in accordance with GOST 15150-69.
Pump models |
Parameters | Nominal motor power, kW |
Weight | |||||
---|---|---|---|---|---|---|---|---|
Capacity, m3/h | Head, m | Rotation speed, rpm |
NPSH required, m |
Efficiency, % | pump, kg | unit, kg | ||
D 4000-95-2 | 4000 | 95 | 1000 | 7 | 88,5 | 1600 | 4600 | 12400 |
D 4000-95-2 | 3200 | 50 | 750 | 5,5 | 88,5 | 630 | 4600 | 8600 |
D 4000-95a-2 | 3700 | 82 | 1000 | 7 | 86,5 | 1250 | 2470 | 11000 |
D 4000-95a-2 | 3000 | 45 | 750 | 5,5 | 86,5 | 630 | 2470 | 8600 |